LEPU / CREATIVE PC-900SNET

Patient monitor measuring oxygen saturation, blood pressure and temperature, ECG, 3.5 col f / f LCD, LED.

Health care products / Patient Monitors


Medical instrument for measuring and monitoring the blood oxygen saturation, blood pressure and body temperature of adult, child and newborn patients.

- External (non-invasive) blood pressure measurement (NIBP).
- It can be adjusted to measure the blood pressure of adults, children and newborns.
- A cuff for measuring blood pressure in children and newborns can be ordered separately (not included).
- Blood pressure measurement with a cuff that can be pulled on the arm (oscillometric measurement).
- Manual, automatic and statistical measurement mode.
- Pressure value limit during heart contraction (systole): 40-255mmHg (adult).
- Pressure value limit when the heart relaxes (diastolic): 10-195 mmHg (adult).
- Mean arterial (MAP) pressure range: 20-215mmHg (adult).
- Pneumatic pressure measurement range: 0mmHg - 300mmHg.
- Pressure value accuracy: +/-3 mmHg.
- Blood pressure measurement margin of error: +/-5 mmHg.
- Maximum deviation from standard: +/-8mmHg.
- Measurement of blood oxygen saturation (oxygen saturation, SpO2).
- Measuring probe that can be clipped onto a finger.
- A measuring probe for children and newborns can be ordered separately (not included).
- Blood oxygen saturation measurement range: 35%-100%.
- Blood oxygen saturation measurement accuracy: 0.4%-5%.
- Pulse waveform measurement range: 30bpm - 240bpm.
- Pulse waveform measurement accuracy: +/-2bpm or 2%.
- Body temperature measurement.
- Body temperature measurement range: 25°C-45°C.
- Body temperature measurement accuracy: +/- 0.2°C.
- ECG function.
- Heart rate range: 20 bpm - 250 bpm.
- ECG accuracy: +/- 2 bmp or 2% (whichever is greater).
- Large, high-brightness LED displays that are clearly visible from afar.
- Display of blood pressure, blood oxygen saturation and heart rate values ​​on the LED display.
- Black/white, 3.5-inch LCD display.
- Display of pulse wave curve (plethysmogram) and system parameters on LCD display.
- Accurate blood pressure measurement with hardware and software overpressure protection.
- Unique blood oxygen saturation measurement technology.
- Display of the development of blood oxygen saturation in the last 12, 24 or 96 hours.
- Store and view the results of 400 blood pressure measurements.
- Store and view 120 hours of heart rhythm curves (ECG).
- 3 levels of alarm.
- Alarm with sound and light signal.
- Nurse call output.
- Built-in thermal paper printer for printing graphs and text information (not included).
- Uninterrupted power supply from a replaceable 12V 2.2Ah battery (not included).
- It can also be used mounted on a table or console.
- Serial communication connection to LEPU CMS central monitoring system (optional).
- 1 finger clip-on blood oxygen saturation measuring probe.
- 1 piece of 25-35cm cuff for blood pressure measurement.
- Meets IEC60601-1 electrical safety class classification (Class I BF and CF).
- Supply voltage: 100-240VAC, 50/60Hz.
- Dimensions: 280mm x 178mm x 200mm.
- CE certification.