securityeurope.eu

HOLDPEAK 760K

Vehicle diagnostic instrument, 4-5-6-8 cylinder, speed, closing angle, pulse.

Instruments / Auto Engine Analyzer


It is a diagnostic instrument suitable for many electronic measurements, which can be used in vehicle electrics.

- Digital diagnostic tool for vehicles.
- Automatic and manual measurement limit switching.
- 3-3/4 digit LCD display with switchable backlight.
- 25mm characters.
- Measurement limit display.
- Specifying a minimum and maximum value limit.
- Reference value measurement.
- Last measured data storage function.
- Automatic negative polarity display.
- Automatic device shutdown after 30 minutes of inactivity.
- Low battery voltage indication.
- Reading time: 3 readings/sec.
- Rotational speed (RPM) measurement range/display resolution/accuracy:
- 600-4000, 4000-12000 (x10RPM) / 1 RPM / +/-2.5%.
- Pulse measurement range/accuracy:
- 0.1ms-10.0ms / +/-2.5%.
- Operating period measurement range/display resolution/accuracy:
- 0.0%-90.0% / 0.1% / +/-2.5%.
- Measurement of closing angle for 4,5,6 and 8 cylinder engines.
- 4-cylinder engine closing angle measurement range/display resolution/accuracy:
- 0°-90.0° / 0.1° / +/-2.5%.
- 5-cylinder engine closing angle measurement range/display resolution/accuracy:
- 0°-72.0° / 0.1° / +/-2.5%.
- 6-cylinder engine closing angle measurement range/display resolution/accuracy:
- 0°-60.0° / 0.1° / +/-2.5%.
- 8-cylinder engine closing angle measurement range/display resolution/accuracy:
- 0°-45.0° / 0.1° / +/-2.5%.
- Temperature measurement range/display resolution/accuracy:
- -50°C - +1100°C / 1°C / +/-2.5%.
- VDC measurement range/display resolution/accuracy (automatic measurement limit switching):
- 400mV / 100uV / +/-2.5%.
- 4V, 40V, 400V, 1000V / 100uV / +/-0.8%.
- Input resistance: greater than 10Mohm.
- Overvoltage protection.
- VAC measurement range (automatic measurement limit switching): 400mV, 4V, 40V, 400V, 750V.
- VAC display resolution: 100uV.
- VAC accuracy 400mV and 750V: +/-3%, 4V, 40V and 400V: +/-1.5%.
- VAC frequency range 400mV and 750V: 50Hz-100Hz, 4V, 40V and 400V: 50Hz-400Hz.
- Input resistance: greater than 10Mohm.
- ADC measurement range/display resolution/accuracy:
- 20A / 10mA / +/-2%.
- AAC measurement range/display resolution/accuracy:
- 20A / 10mA / +/-2%.
- AAC frequency range: 50Hz-400Hz.
- Resistance measurement range / accuracy (automatic measurement limit switching):
- 400ohm / +/-1.5%.
- 4kohm / +/-1%.
- 40kohm / +/-1%.
- 400kohm / +/-1%.
- 4Mohm / +/-1%.
- 40Mohm / +/-2.5%.
- Frequency measurement range/display resolution/accuracy (automatic measurement limit switching):
- 100Hz / 0.01Hz / +/-0.5%.
- 1kHz / 0.01Hz / +/-0.5%.
- 100kHz / 0.01Hz / +/-0.5%.
- 200kHz / 0.01Hz / +/-0.5%.
- Capacity measurement range/display resolution/accuracy (automatic measurement limit switching):
- 40nF / 10pF / +/-2.5%.
- 400nF / 10pF / +/-1.5%.
- 4uF / 10pF / +/-1.5%.
- 40uF / 10pF / +/-2.5%.
- 100uF / 10pF / +/-2.5%.
- Diode test, 1.5V/1.5mA.
- Tear test with sound signal.
- Measuring tape.
- 2 insulated alligator clips.
- Temperature measuring probe.
- Support bracket that can be folded out 180°.
- Black fabric instrument bag.
- Power supply: 9VDC from 6F22 battery.
- Operating temperature: 0°C-50°C.
- Operating humidity: maximum 70%.
- Dimensions: 190mm x 88.5mm x 27.5mm.
- Weight: 320g (with battery).
- CE certification.