securityeurope.eu

HOLDPEAK 760J

Vehicle diagnostic instrument, 3-4-5-6-8 cylinder, RPM, closing angle, pulse, temperature.

Instruments / Auto Engine Analyzer


It is a diagnostic instrument suitable for many electronic measurements, which can be used in vehicle electrics.

- Digital diagnostic tool for vehicles.
- Manual measurement limit switching.
- 3-1/2 digit LCD display with switchable backlight.
- Maximum value display: 1999.
- Measurement limit display.
- Specifying a minimum and maximum value limit.
- Last measured data storage function.
- Automatic negative polarity display.
- Automatic device shutdown after 30 minutes of inactivity.
- Low battery voltage indication.
- Reading time: 3 readings/sec.
- Rotational speed (RPM) measurement range/accuracy:
- 600-10000 / +/-1.5%.
- Pulse measurement range/accuracy:
- 0.1ms-10.0ms / +/-2.5%.
- Operating period measurement range/display resolution/accuracy:
- 0.0%-90.0% / 0.1% / +/-2.5%.
- Measurement of closing angle for 3,4,5,6 and 8 cylinder engines.
- 3-cylinder engine closing angle measurement range/accuracy:
- 0°-120.0° / +/-1.5%.
- 4-cylinder engine closing angle measurement range/accuracy:
- 0°-90.0° / +/-1.5%.
- 5-cylinder engine closing angle measurement range/accuracy:
- 0°-72.0° / +/-1.5%.
- 6-cylinder engine closing angle measurement range/accuracy:
- 0°-60.0° / +/-1.5%.
- 8-cylinder engine closing angle measurement range/accuracy:
- 0°-45.0° / +/-1.5%.
- Temperature measurement range/display resolution/accuracy:
- -20°C-1000°C / 1°C / 0-400°C: +/-0.75%, 400°C-1000°C: +/-1.5%.
- -4°F-1800°F / 1°F / 0-750°F: +/-0.75%, 750°F-1800°F: +/-1.5%.
- VDC measurement range/display resolution/accuracy (automatic measurement limit switching):
- 200mV / 0.1mV / +/-0.5%.
- 2V / 1mV / +/-0.5%.
- 20V / 10mV / +/-0.5%.
- 200V / 100mV / +/-0.5%.
- 1000V / 1V / +/-1.5%.- Input resistance: greater than 10Mohm.
- Input resistance in VDC measurement mode: 10Mohm.
- Overvoltage protection.
- VAC measurement range/display resolution/accuracy:
- 2V / 1mV / +/-1.5%.
- 20V / 10mV / +/-1.5%.
- 200V / 100mV / +/-1.5%.
- 750V / 1V / +/-2.5%.
- AC voltage frequency range: 40Hz-400Hz (2V-200V), 40Hz-200Hz (750V).
- Input resistance in VAC measurement mode: 10Mohm.
- ADC measurement range/display resolution/accuracy:
- 20A / 10mA / +/-2%.
- Overcurrent protection with internal 20A fusible fuse.
- Resistance measurement range/display resolution/accuracy:
- 200ohm / 100mohm / +/-1.5%.
- 20kohm / 10ohm / +/-1%.
- 200kohm / 100ohm / +/-1%.
- 20Mohm / 10kohm / +/-1%.
- 200Mohm / 1kohm / +/-2.5%.
- Diode test, 1.5V/1mA.
- Tear test with sound signal.
- Transistor hFE testing.
- Measurement of NPN and PNP transistors.
- Test voltage/current: Ib=10uA/Vce=3V.
- Measuring tape.
- 2 insulated alligator clips.
- Temperature measuring probe.
- Support bracket that can be folded out 180°.
- Black fabric instrument bag.
- Power supply: 9VDC from 6F22 battery.
- Operating temperature: 0°C-40°C.
- Operating humidity: maximum 85%.
- Dimensions: 190mm x 88.5mm x 27.5mm.
- Weight: 320g (with battery).
- CE certification.